Siklu - MultiHaul SSID Error
Edited
Problem Description:
When configuring an SSID and Passkey on a Siklu MultiHaul BU-100 or TU-200 radio the following error may be experienced: % Ambiguous command: set ssid?
This is a known bug that affected a small batch of radios that shipped in 2019.
How to fix:
The bug can be resolved by uploading a special "MH-RECOVERY" firmware image file to the affected radio, rebooting the radio, and then upgrading to the latest version of firmware following this process. The recovery firmware image can be found at the bottom of this article.
For a detailed process on upgrading the firmware on Siklu radios, please see step three (HTTPS upgrade) in our firmware upgrade guide Siklu - EtherHaul Firmware Upgrade Procedure