CNUT Upgrade Process for PMP 450 SM Units

Edited

Description:

This guide is to document the upgrade process of PMP 4XX SM Units using CNUT 

Method:

Step1: Add Network Elements

mceclip0.png

mceclip1.png

Discovery Target Options:

  • Element Host Name(s)/IP Address(es)

Enter 1 or more Host Names/IP Addresses for each Element to Add. Enter 1 line per element.(You can copy and paste text into this field). Example     169.254.1.1

                                                                            169.254.1.2

  • Scan IP Address Range

Enter 1 or more IP addresses or range of IP addresses to scan. Enter 1 line per IP/range. An element will only be added if the IP is accessible. Example 169.254.1.1-169.254.1.100

mceclip2.png

Step 2:  Ensure the SNMP Read/Write Community match the CNUT & the PMP 450 Units. Check the  Read/Write button for the SNMP Community String 1 Provisioning.

mceclip7.png

mceclip8.png

 

Step 3:  Navigate to View>Refresh/Discover Selected Network Elements

mceclip3.png

mceclip4.png

Step 4: Navigate to Update>Manage Packages 

Click Add and select the Firmware pkg file

mceclip5.png

mceclip6.png

Step 5: Navigate to Update>Configure. Check Select File Server Type : CNUT HTTP Server, then check the box for the PMP 450 SM Type

mceclip9.png

Step 6: Navigate to Update>Update Selected Network Elements

Click Yes to Update Network

mceclip10.png

mceclip11.png

mceclip12.png

mceclip13.png

mceclip14.png

 

 

 

Was this article helpful?

Sorry about that! Care to tell us more?

Thanks for the feedback!

There was an issue submitting your feedback
Please check your connection and try again.