CNUT Upgrade Process for PMP 450 SM Units
Description:
This guide is to document the upgrade process of PMP 4XX SM Units using CNUT
Method:
Step1: Add Network Elements
Discovery Target Options:
Element Host Name(s)/IP Address(es)
Enter 1 or more Host Names/IP Addresses for each Element to Add. Enter 1 line per element.(You can copy and paste text into this field). Example 169.254.1.1
169.254.1.2
Scan IP Address Range
Enter 1 or more IP addresses or range of IP addresses to scan. Enter 1 line per IP/range. An element will only be added if the IP is accessible. Example 169.254.1.1-169.254.1.100
Step 2: Ensure the SNMP Read/Write Community match the CNUT & the PMP 450 Units. Check the Read/Write button for the SNMP Community String 1 Provisioning.
Step 3: Navigate to View>Refresh/Discover Selected Network Elements
Step 4: Navigate to Update>Manage Packages
Click Add and select the Firmware pkg file
Step 5: Navigate to Update>Configure. Check Select File Server Type : CNUT HTTP Server, then check the box for the PMP 450 SM Type
Step 6: Navigate to Update>Update Selected Network Elements
Click Yes to Update Network